Skip to content

Conversation

PengZhang13
Copy link
Contributor

As I said in the issue, I think the E0 here should be a negative value as -1.45

I checked the source literature.
It looks like the parameters for this entry are taken from the rate for i-Butane T000 site.
They were written as logA = 3.41, n = 1.9, B = -730 in the original paper.
Then we have B*1.987/1000= -1.45
So maybe it's a typo?

Source paper link: [http://onlinelibrary.wiley.com/doi/10.1002/kin.550230506/epdf]
Cohen - 1991 - Are reaction rate coefficients additive Revised t.pdf
P412

@PengZhang13 PengZhang13 closed this Jun 1, 2016