-
Notifications
You must be signed in to change notification settings - Fork 6
/
Copy pathsen44.h
177 lines (156 loc) · 5.52 KB
/
sen44.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
/*
* Copyright (c) 2018, Sensirion AG
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions are met:
*
* * Redistributions of source code must retain the above copyright notice, this
* list of conditions and the following disclaimer.
*
* * Redistributions in binary form must reproduce the above copyright notice,
* this list of conditions and the following disclaimer in the documentation
* and/or other materials provided with the distribution.
*
* * Neither the name of Sensirion AG nor the names of its
* contributors may be used to endorse or promote products derived from
* this software without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
* AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE
* LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
* CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
* SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
* CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
*/
#ifndef SEN44_H
#define SEN44_H
#ifdef __cplusplus
extern "C" {
#endif
#include "sensirion_arch_config.h"
#define SEN44_MAX_SERIAL_LEN 80
#define SEN44_ERR_NOT_ENOUGH_DATA (-1)
#define SEN44_ERR_STATE_MASK (0x100)
#define SEN44_IS_ERR_STATE(err_code) (((err_code) | 0xff) == 0x1ff)
#define SEN44_GET_ERR_STATE(err_code) ((err_code)&0xff)
struct sen44_measurement{
uint16_t mc_1p0;
uint16_t mc_2p5;
uint16_t mc_4p0;
uint16_t mc_10p0;
int16_t voc_index;
int16_t ambient_humidity;
int16_t ambient_temperature;
};
/**
* sen44_get_driver_version() - Return the driver version
* Return: Driver version string
*/
const char *sen44_get_driver_version(void);
/**
* sen44_probe() - check if SEN44 sensor is available and initialize it
*
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_probe();
/**
* sen44_get_serial() - retrieve the serial number
*
* Note that serial must be discarded when the return code is non-zero.
*
* @serial: Memory where the serial number is written into as hex string (zero
* terminated). Must be at least SPS_MAX_SERIAL_LEN long.
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_get_serial(char *serial);
/**
* sen44_start_measurement() - start measuring
*
* Once the measurement is started, measurements are retrievable once per second
* with sen44_read_measurement.
*
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_start_measurement();
/**
* sen44_stop_measurement() - stop measuring
*
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_stop_measurement();
/**
* sen44_read_measurement() - read a measurement
*
* Read the last measurement.
*
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_read_measurement(struct sen44_measurement *measurement);
/**
* sen44_get_fan_auto_cleaning_interval() - read the current auto-cleaning
* interval
*
* Note that interval_seconds must be discarded when the return code is
* non-zero.
*
* @interval_seconds: Memory where the interval in seconds is stored
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_get_fan_auto_cleaning_interval(uint32_t *interval_seconds);
/**
* sen44_set_fan_auto_cleaning_interval() - set the current auto-cleaning
* interval
*
* @interval_seconds: Value in seconds used to sets the auto-cleaning interval
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_set_fan_auto_cleaning_interval(uint32_t interval_seconds);
/**
* sen44_get_fan_auto_cleaning_interval_days() - convenience function to read
* the current auto-cleaning interval in days
*
* note that the value is simply cut, not rounded or calculated nicely, thus
* using this method is not precise when used in conjunction with
* sen44_set_fan_auto_cleaning_interval instead of
* sen44_set_fan_auto_cleaning_interval_days
*
* Note that interval_days must be discarded when the return code is non-zero.
*
* @interval_days: Memory where the interval in days is stored
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_get_fan_auto_cleaning_interval_days(uint8_t *interval_days);
/**
* sen44_set_fan_auto_cleaning_interval_days() - convenience function to set the
* current auto-cleaning interval in days
*
* @interval_days: Value in days used to sets the auto-cleaning interval
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_set_fan_auto_cleaning_interval_days(uint8_t interval_days);
/**
* sen44_start_manual_fan_cleaning() - Immediately trigger the fan cleaning
*
* Note that this command can only be run when the sensor is in measurement
* mode, i.e. after sen44_start_measurement() without subsequent
* sen44_stop_measurement().
*
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_start_manual_fan_cleaning();
/**
* sen44_reset() - reset the SEN44
*
* Return: 0 on success, an error code otherwise
*/
int16_t sen44_reset();
#ifdef __cplusplus
}
#endif
#endif /* SEN44_H */